RKI Instruments 65-2484RK User Manual

Page 7

Advertising
background image

65-2484RK Multi Point Detector • 3

NOTE: The following symbol on the detector label is a caution to the user to refer to this

documentation for installation and operation instructions:

WARNING: When using the 65-2484RK, you must follow the instructions and warnings

in this manual to assure proper and safe operation of the 65-2484RK and to
minimize the risk of personal injury. Be sure to maintain and periodically
calibrate the 65-2484RK as described in this manual.

Sampling

Method

Diffusion

Detection

Range

LEL: 0 to 100 %LEL (lower explosive limit)
O

2

: 0 to 25 %volume

CO: 0 to 300 ppm (parts per million)
H

2

S: 0 to 100 ppm (parts per million)

AsH

3

: 0 - 1.50 ppm

Cl

2

: 0 - 3.00 ppm

HCN: 0 - 15.0 ppm
NH

3

: 0 - 75.0 ppm

PH

3

: 0 - 1.00 ppm

SO

2

: 0 - 6.00 ppm

Response Time

90% in 30 seconds

Accuracy

Catalytic Combustible Gas:
± 5% of reading or ± 2% LEL (whichever is greater)
IR Combustible Gas:
± 5% of reading or ± 2% of full scale (whichever is greater)
Oxygen:
± 0.5% O

2

Carbon Monoxide:
± 5% of reading or ± 5 ppm CO (whichever is greater)
Hydrogen Sulfide:
± 5% of reading or ± 2 ppm H

2

S (whichever is greater)

ESM-01:
± 10% of reading or ± 5% of full scale (whichever is greater)

Operating

Temperature

23°F to 104°F (-5°C to 40°C)

Table 1: Specifications

!

Advertising