3 Product Components

3-6. Block diagram

TAN-5000

- 12 -

3-6. Block diagram

TAN-5000













Indicator/alarm unit (option)






Controller

(CPU)

POWER INPUT

(24 VDC)

Power supply part

Common gas alarm contact
(ALM1, ALM2)
Common fault alarm contact
(FAULT)
* Standard setting of contact

activation
- De-energized

(De-energized at a normal
environment)

- "a" contact

(Closed contact at an alarm
time)

Alarm contact controller

Output
Reset signal

Input
Gas alarm signal (ALM1, ALM2)
Fault alarm signal (FAULT)

*1: The buzzer stop switch is mounted only

if the alarm activation is the lock-in type.

Display
(POWER) (FAULT)

Operating unit
(RESET) (BUZZER STOP) *1

Buzzer