RKI Instruments TAN-5000 Series User Manual

Page 30

Advertising
background image

7 Product Specifications

7-1. List of specifications

TAN-5000

- 30 -

[TAN-5000L]

Power display

POWER lamp on or blinking (green)

Gas alarm display

Buzzer

Gas alarm pattern

Lock-in

Gas alarm contact

No-voltage contact 1a or 1b (2 step independent)
De-energized (energized at an alarm) or energized (de-energized at an alarm)

Fault alarm/self
diagnosis

System abnormalities, indicator/alarm unit common fault alarm

Fault alarm display

FAULT lamp on (yellow) with or without buzzer sounds

Fault alarm pattern

Auto-reset

Fault alarm contact

No-voltage contact 1a or 1b
De-energized (energized at an alarm) or energized (de-energized at an alarm)

Contact capacity

100 VAC - 0.5A/30 VDC - 1.5A (resistant load)

Power supply

24 VDC (21.6 – 26.4 VDC)

Power consumption

Maximum 2 W

Operating
temperatures

-10 - 40

°C (at a constant condition)

Operating humidities

10 to 90%RH (Non-condensing)

Structure

Card type with front display used enclosed in a case (a single-unit or multi-unit
case)

External dimensions

Approx. 29.6 (W) x 120 (H) x 92 (D) mm (projection portions excluded)

Weight Approx.

80g

* Specifications subject to changes without notice.