Unst – Salter 1048 HBBKDR Heston Blumenthal Precision Digital Measuring Jug User Manual

Page 3

Advertising
background image

3

GB

The Salter Precision Digital Measuring Jug can be used to measure both weight

and volume, taking into account for the different densities of oil, milk and water.

The jug features an easy-to-read display positioned in the handle. The clear jug is

detachable.

BATTERIES

Remove isolator tab before first use.

Insert 1 x CR2450 3V lithium cell. Ensure +/- terminals are the correct way round.

N.B. this battery type is widely available online and can also be sourced from our

online shop at www.salterhousewares.com

OPERATION

To switch on, press on the handle of the jug. Wait for the display to show zero*.

Use the Mode (M) and Unit (U) buttons to select the required ingredient and measure.

(see section on Mode function below for all available options)

With the jug resting on a flat surface, add the ingredient to be weighed using the

markings on the jug as an additional guide if required. The display will show the

weight reading.

If filling at a tap, first ensure the display is set to zero. Lift the jug and fill, judging

the level by the markings on the jug. Place the jug on a flat surface. The display will

show the accurate weight or volume reading. Lift to pour out or add more liquid as

required until the amount is correct for your recipe.
*If, on switching on the product with an empty jug, the display gives a weight reading

greater than zero you may need to calibrate the jug. Calibration is ONLY needed when

the reading of the EMPTY jug is higher than zero.

With the clean, empty jug in-place on the base, turn on the unit with a single

press of the button. Ensuring the jug is positioned on a level surface, press and

hold for 6 seconds until ‘CAL’ flashes on the screen. Do not hold or touch the jug

when CAL is showing.

The display shows zero – calibration is complete.

MODE FUNCTION

Select from 5 pre-set ingredients (water, milk, oil, flour and sugar) using the Mode

(M) button. The software is programmed to take into account the different densities

of different ingredients. This means that the scale can accurately be used to measure

volumes as well as by weight. Change between weight and volume measures by

pressing the Unit (U) button.

Mode

Display shows

Available Units

Scale

SCL

g, oz

Water

WTR

Ml, fl.oz, cups

Milk

MLK

Ml, fl.oz, cups

Oil

OIL

Ml, fl.oz, cups

Flour

FLR

g, oz, cups

Sugar

SGR

g, oz, cups

NOTE: There are different types of milk, oil, sugar or flour in the market. Different

types, brands & origins of the same ingredient have different density. For this

reason, some variation on the volume measurement will occur depending on the

type of ingredients you are using.

TO ADD AND WEIGH

To reset the display between ingredients press button once at anytime during

weighing. To find out the total weight of the individually weighed ingredients,

press button once, the Tare symbol will remove from the display and the total

weight of all previously zeroed weights will be shown.

TO DETACH THE JUG

Press the button below the handle to unlock and detach the jug from the base.

AUTO-OFF/MANUAL SWITCH OFF

To conserve battery life the display will automatically switch off after 5 minutes.

To manually switch off the scale press and hold for 3 secs.

WARNING SYMBOLS

err

– Overload

unst

– Scale is unstable. Place on a flat surface then restart.

Lo

– Low battery

UNST CLEANING & CARE

CLEANING AND CARE

The clear jug part can be removed from the base and washed by hand. The base and

handle part must not be submerged in water. Clean only with a damp cloth. Do not

use chemical or abrasive cleaning agents.

Keep away from hot surfaces.

NOT SUITABLE for use in Microwave ovens.

WEEE EXPLANATION

This marking indicates that this product should not be disposed with other

household wastes throughout the EU. To prevent possible harm to the

environment or human health from uncontrolled waste disposal, recycle it

responsibly to promote the sustainable reuse of material resources. To return your

used device, please use the return and collection systems or contact the retailer

where the product was purchased. They can take this product for environmental

safe recycling.

GUARANTEE

This product is intended for domestic use only. Salter will repair or replace the

product, or any part of this product, (excluding batteries) free of charge if within

15 years of the date of purchase, it can be shown to have failed through defective

workmanship or materials. This guarantee covers working parts that affect the

function of the scale. It does not cover cosmetic deterioration caused by fair wear

and tear or damage caused by accident or misuse. Opening or taking apart the

scale or its components will void the guarantee. Claims under guarantee must be

supported by proof of purchase and be returned carriage paid to Salter (or local

Salter appointed agent if outside the UK). Care should be taken in packing the

scale so that it is not damaged while in transit. This undertaking is in addition to a

consumer’s statutory rights and does not affect those rights in any way.

For UK Sales and Service contact HoMedics Group Ltd, PO Box 460, Tonbridge, Kent,

TN9 9EW, UK. Helpline Tel No: (01732) 360783. Outside the UK contact your local

Salter appointed agent.