ECO-X / IL-X Manual
IM100117
RD: JAN 2013
RL: 05D - BA

24

IS THERE VOLTAGE (24V) TO IG-
NITION CONTROL MODULE FROM
TRANSFORMER ?

→CHECK ELECTRICAL CONNECTION FROM

TRANSFORMER TO IGNITION CONTROL
MODULE.

→CHECK PROPER DISTRIBUTION WIRE GAUGE
→ENSURE LOW VOLTAGE WIRES ARE
PROPERLY INSTALLED, WIRING POLARITY
IS CRITICAL
→CHECK VA RATING ON THE TRANSFORMER.

40 VA FOR 1ST HEATER + 20 VA FOR EACH
ADDITIONAL HEATER IN THE ZONE.

YES

NO

IS THERE A SPARK AT IGNITION
SPARK IGNITER?

REFER TO SECTIONS 19 AND 20 BEFORE
PROCEEDING
→ENSURE THE IGNITER GAP IS 1/4" WIDE
(6MM)
→ENSURE THE FLAME SENSOR IS WITHIN
1/4” TO 1/8" ABOVE CERAMIC TILE
→CHECK SPARK IGNITER CE RAMIC FOR
CRACK, REPLACE SPARK IGNITER IF NECES
SARY
→CHECK HI-VOLTAGE WIRE C O N N E C T I O N
FROM SPARK IGNITER TO IGNITION MODULE
→ENSURE HIGH VOLTAGE S P A R K S

A R E

GENERATED ON THE IGNITION CONTROL
TERMINAL BY FOLLOWING THE STEPS AS
SHOWN

BELOW:

-SHUT OFF ELECTRICAL POWER
-REMOVE THE HI-VOLTAGE WIRE ON THE
IGNITION CONTROL TERMINAL

WARNING: BEFORE REMOVING HI-VOLTAGE
WIRE, ELECTRICAL POWER TO THE SYSTEM
MUST BE SHUT OFF. THIS TERMINAL CARRIES
30,000 AC VOLTS.

REFER TO SECTION 20 FOR PROCEDURE

YES

NO

CONT’D