Schwank IEP-2024 User Manual

Page 8

Advertising
background image

8

IM110810

RD: AUGUST 2011

RL; 1A

BA

InfraSave IEP-2024 Manual

ft [m]

ft [m]

ft [m]

ft [m]

ft

2

[m

2

]

watts / ft

2

Min.

7 [2.1]

8.8 [2.7]

8.5 [2.6]

16 [4.9]

108 [10.1]

13.9

Max.

8 [2.4]

9.8 [3.0]

9.2 [2.8]

18 [5.5]

133 [12.4]

11.3

Min.

8 [2.4]

9.8 [3.0]

9.2 [2.8]

18 [5.5]

133 [12.4]

15.0

Max.

9 [2.7]

11 [3.4]

10 [3.0]

20 [6.1]

165 [15.3]

12.1

Min.

10 [3.0]

12 [3.6]

11.2 [3.4]

23 [7.0]

205 [19.0]

19.5

Max.

11.5 [3.5] 13.5 [4.1]

14 [4.3]

27.5 [8.4]

275 [25.4]

14.5

Min.

12 [3.7]

14 [4.3]

15 [4.6]

29.5 [9.0]

315 [29.2]

19.0

Max.

15 [4.6] 14.4 [4.4]

17.7 [5.4]

32 [9.8]

360 [33.4]

16.7

IEP 6024

6000

IEP 1520/4 1500

IEP 2024

E

Average Heat

Coverage

IEP 4024

4000

D

Area

Heated

2000

C

Outer

Perimeter

A

Distance

Out

B

Under

Heater

Recom-

mended

Min /

Max

Input

Watts

Model

.

H

Height Above

Floor/Deck

FIGURE 1: RECOMMENDED MOUNTING: COMFORT AREA COVERAGE

TABLE 1: RECOMMENDED MOUNTING: COMFORT AREA COVERAGE

Approximate Angle of Heat

Dispersion from heater

The design information presented here is intended as a guideline. The accuracy of determin-

ing or estimating all factors above will affect performance and satisfaction. Air movement in

particular will affect comfort.

 Refer to design guidelines on previous page.
 Refer to Required Minimum Clearances: Table 2 & Figure 2, Page 10