CHAPTER IV -25
M-8
BD failure
Possible cause
Step
Check
Result
Remedy
Harness
connection
failure
1
Is connector P4 on the driver
PCB secured correctly?
No
Connect it securely.
M-9
Scanner failure
Possible cause
Step
Check
Result
Remedy
Harness
connection
failure
1
Is the connection of the
scanner motor connector P2 on
the driver PCB secured?
No
Reconnect the connectors
securely.
Power supply
input
2
Is the voltage between pins 1
(+24VDC) and 2 (GND) of
connector P2 on the driver PCB
24 Volts DC?
No
Check if +24VDC is supplied
between pins 4.5 (+24VDC)
and 2.3 (+24VRET) of
connector P13 on the driver
PCB. If not, check the power
supply output on the low-
voltage power supply PCB.
Yes
Replace the scanner unit.