17. LIGHTING INSTRUCTIONS

Refer to the lighting instructions on the inside
cover of the burner housing. Again, if the
unit goes off on safety, main power to the
unit must be manually interrupted for a 30
second reset period before the heater can be
restarted.

NOTE:
On initial installation, the unit
may lock out on safety owing to
the length of time required to
bleed air from the gas piping
system.

18. RECOMMENDED MAINTENANCE

THE SCHWANK TUBE HEATER BURNER IS COMPLETELY FACTORY ASSEMBLED
AND TESTED. ANY ALTERATION VOIDS THE CSA CERTIFICATION AND
MANUFACTURER’S WARRANTY. FOR ADDITIONAL INFORMATION, CONTACT
YOUR LOCAL DISTRIBUTOR OR SCHWANK INC.

1. Inspect the venting system each heating sea-

son and repair or replace worn parts as
required.

2. Check the inlet air opening and the blower

periodically, cleaning off any lint or foreign

matter, as it is important that the flow of com
bustion and ventilation air must not be ob

structed. In addition we recommend the entire
system be checked once a year by a qualified
service technician.
3. Lubricate Blower Motor, by adding several
drops of oil to oil ports located on the left hand
side of the motor .