P:\INSTALLATION INST\Electrified Lockset\INST-Z7800 03/05 Page 2

B. Strike Installation:

1. Align strike template on jamb. Be sure to keep 3/8" distance between lock centerline and strike
centerline. Recess 5/32" for flush fit of strike and dust box.

2. Mortise jamb according to measurement of strike template. Then fit strike and dust box into frame
and secure into place with supplied screws.

C. Install Lockcase
Make sure the lock hand matches the door hand, use the following diagram to determine the hand of door.

4-7/8"

3-17/32"

CL

Strike

Lock CL

3/8"

3/8"

1" Holes

1-1/8" Deep

CL

Jamb

LH
Left Hand

LHRB
Left Hand
Reverse Bevel

INSIDE OF DOOR

OUTSIDE OF DOOR

RH

Right Hand

RHRB

Right Hand

Reverse Bevel

INSIDE OF DOOR

OUTSIDE OF DOOR