SDC 45 SERIES ELECTRIC STRIKES User Manual
Page 3

P:\INSTALLATION INST\ELECTRIC STRIKES\INST-45\INST-45.vsd REV K 12-13 Page 3
Horizontal Adjustment
Remove Faceplate. Loosen Horizontal Adjustment Screws and slide Die Cast
Body out as needed. Retighten Adjustment Screws and replace Faceplate.
Horizontal Adjustment
Screws
Die Cast Body
Keeper/Deadlocked: Purple – COM
Brown - N/O
Yellow - N/C
Latch Status: Orange - COM
White - N/O
Grey - N/C
Solenoid: Black, Red, Blue & Green
Electrical Data:
Dual Voltage: 200/100mA @ 12/24VDC
140/70mA @ 12/24VAC
Monitoring:
Latch Status: SDPT, dry 3Amp @ 30V (standard)
Keeper Closed and Deadlocked (standard)
Keeper Open/Closed Status: SPDT, Dry 3Amp @ 30V
(optional)
Keeper-Open/Closed:
Wht/Blk – COM
Yel/Blk - N/O
Org/Blk - N/C
The electric door strike shall be
installed in such a way as not to impair
the operation of an emergency exit or
panic hardware mounted on the door.
Wire leads must not be connected to
conductors larger than18AWG
Notes:
Red
Black
Blue
Green
Red
Black
Blue
Green
12V
24V
MOV