INSTALLATION INSTRUCTIONS PSB560

SURE EXIT TOUCHPAD

P:\INSTALLATION INST\EXITBARS KEY_EXIT SWITCHES\INST-PSB560.vsd REV C2 01-13 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

The PSB560 is a pressure sense bar designed to release any magnetic lock with minimal applied pressure
and requires no prior knowledge or effort for free egress. The available standard lengths fit standard door
openings of 36". 42" and 48" (with stops no greater than 5/8”) without cutting.

1. Using a level, mark a horizontal center line at the standard 40" to 42"

from the finished floor.

2. With the template provided, mark all mounting holes and the wire hole

by placing the template on the face of the door against the door jamb
with door in the closed position as illustrated in Figure A.

3. Using a 3/8” drill bit, drill four (4) mounting holes through the door and

the one (1) wire mounting hole in the hinge side of the door.

4. Install the sexbolts provided from the outside of the door.
5. Install the bar mounting bracket to the latch side of the door using the

1/4-20 screws provided.

6. Insert the bar rail under the tab of the installed latch side bracket.
7. Position the bar against the door and install the second bar mounting

bracket using the 1/4-20 mounting screws provided. Make sure the
bar rail is located under the bracket’s mounting tab.

8. NOTE: If bar length needs be cut, install both mounting brackets on

the door and measure between upright tabs on bracket for proper
length of bar.

9. Pull wire cable through the door’s wire transfer (see Figure B for wiring

connections).

FINAL ASSEMBLY AND TESTING

1. Turn on the power.
2. Depress the bar and verify proper orientation. The sensitivity is fac-

tory set and should not need adjustment under normal conditions.

3. Install the end caps with the #8-32 screws provided.

SENSITIVITY ADJUSTMENT

Sensor Bar may be installed without sensor adjustments. Calibration is not required. If a higher activation
pressure setting is desired to inhibit tampering from the outside, the sensors may be adjusted from 5 lbs.
through 15 lbs. without removing the bar from the door.
1. Open the door.
2. Remove the latch side end cap.
3. Slide the touch bar to one side.
4. Adjust the pot on the electronics modules to the desired sensitivity.
5. Slide the bar back into position and test the sensitivity.

NOTE: Care must be taken to properly align the sensor assemblies when sliding the bar back into position.

6. Reinstall end cap.

LISTED 4J82
BURGLARY - RESISTANT
ELECTRIC LOCKING MECHANISM
ACCESS CONTROL ACCESSORY

SDC PSB560

Armored
Power Transfer

EmLock

Devices are to be installed in accordance with the applicable
codes and local authorities having jurisdiction. These
devices are not intended to replace Listed panic hardware.

PATENTED