Appendix – STEMCO Tractor Interface Module User Manual

Page 17

Advertising
background image

17

APPENDIX

Troubleshooting

Try the recommended actions to correct issues. Additional support is available by calling
Stemco customer support at 800-527-8492.

TIM

– OBC Communications Issues

Symptom

– Line 1 NOT shown on PeopleNet display & TIM Light is on or flashing

1) This indicates that the TIM is not communicating successfully with the OBC. Review

the installation instructions to ensure the g3 services port on the PeopleNet computer is
configured correctly. Ensure the cable is connected securely on both ends.

LED Indicator Codes

Light

Description

Recommended Actions

Single Blinking
RED

Communication not working with
PeopleNet OBC

1) Review Installation Instructions for
OBC g3 services port configuration. 2)
Replace cable.
3) Call Stemco Customer Service

Double Blinking
RED

Communication working but PeopleNet
OBC is sending error codes to the TIM
which the TIM is not able to correct.

1) Call Stemco Customer Service

Solid BLUE

Boot Loader cannot find a valid firmware
image.

1) Call Stemco Customer Service

Blinking BLUE Voltage supplied to the TIM is below 5

Volts.

1) Measure voltage on 9 pin D
connector end of cable. Pin 9 (from
+10 to +28VDC); pin 5 DC Common(-)

Advertising