B&B Electronics 3PCI2 User Manual

Page 49

Advertising
background image

44

Chapter 6

Documentation Number 3PCI2-0903 Manual

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Chapter 6:

RS-422/RS-485 Connections/Operation

These modes support 2 channels - transmit and receive. The
pinouts of the DB-9 male connector are given in Table 4.

Connect only to specified pins for proper operation.

2-Wire RS-485 Connections

Fig. 6.1

2-Wire RS-485: Your cables must bridge pins #1 & #3 and pins #2 &
#9 in order to receive and transmit. Connect from Pin #2 to Data
B(+) of your devices and from pin #3 to Data A(-) of your devices.
Make sure your Mode/Jumpers are set, and that the driver Setting
for DTR Operation is RS-485 Mode in the Device Manager.

Note that the EIA RS-422 Specification labels data lines with an "A"
and "B" designator. Some RS-422 or RS-485 equipment uses a "

"

and "+" designator. In most cases, the "A" line is the equivalent of
the "

" line and the "B" line is the equivalent of the "+" line. Some

device manufacturers may not follow the standard designation for
RS-422 or RS-485, using the A connection for “+” and the B for “-“.
In such cases, reversing the line pair permits operation.

Table 4: RS-422/485 Pinouts

Name

Description

Direction

DB9M

Pin

RD(A)

−−−−

Receive Data A

Input

1

TD(B) +

Transmit Data B

Output

2

TD(A)

−−−−

Transmit Data A

Output

3

GND

Signal Ground

------

5

RD(B) +

Receive Data B

Input

9