B-2

Appendix B

Documentation Number 3PCI2-0903 Manual

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

With 2-wire RS-485 mode operation, your connection cable must
jumper TD(A) to RD(A) and TD(B) to RD(B). Connect from TD(A)
and TD(B) to the Data A(

−−−−

) and Data B(+) wires of your RS-485

network.

See Chapter 6 for example connections.

Note that the EIA RS-422 Specification labels data lines with an "A"
and "B" designator. Some RS-422 equipment uses a "

" and "+"

designator. In almost all cases, the "A" line is the equivalent of the
"

" line and the "B" line is the equivalent of the "+" line.

More

information on RS-422 communications can be found in the B&B
Electronics RS-422/485 Application Note (available on our
website)

.

Table B.3: RS-422/485 Pinouts

Name

Description

Direction

DB9M

Pin

RD(A)

−−−−

Receive Data A

Input

1

TD(B) +

Transmit Data B

Output

2

TD(A)

−−−−

Transmit Data A

Output

3

GND

Signal Ground

------

5

RD(B) +

Receive Data B

Input

9