Specifications, Technology, Standards – Weidmuller IE-MC-VL Series - Industrial Ethernet Media Converters User Manual

Page 13: Ieee802.3, 802.3u, link fault pass-through, Interface, Rj45 ports, 10/100baset(x), Fiber ports, 100basefx (sc, st connectors available), Led indicators

Advertising
background image

Specifications

Technology

Standards

IEEE802.3, 802.3u, Link Fault Pass-Through

Interface

RJ45 ports

10/100BaseT(X)

Fiber ports

100BaseFX (SC, ST connectors available)

LED Indicators

Power, Fault, 10/100M, Full Duplex/Collision

Dip Switch

Port break alarm mask, 100BaseFx Full/Half
duplex selection

Alarm Contact

One relay output with current carrying capacity of
1A @ 24 VDC

Optical Fiber

Multi
mode

Single
mode, 40

Distance, km

5 40

Wavelength, nm

1310 1310

Min. TX Output, dBm

-20 -5

Max. TX Output, dBm

-14 0

Sensitivity, dBm

-34 to -30

-36 to -32

Recommended Diameter

62.5/125 9/125

(Core/Cladding) μm (1

dB/km,

800 MHz

× km)

Power

Input Voltage

24 VDC (12 to 45 VDC); Redundant inputs

Input Current (@24V)

0.16 A

Connection

Removable Terminal Block

Overload Current Protection 1.1 A
Reverse Polarity Protection Present
Mechanical

Casing

IP30 protection, aluminum case

Dimensions (W x H x D)

53.6 x 135 x 105 mm

Weight

0.63 kg

Installation DIN-Rail,

Wall

Mounting

Environmental

Operating Temperature

0 to 60°C (32 to 140

o

F),

Storage Temperature

-40 to 85°C (-40 to 185

o

F)

Ambient Relative Humidity 5 to 90% (non-condensing)
Regulatory Approvals

Safety

UL60950, UL 508, CSA C22.2 No. 60950,
EN60950

Hazardous Location

UL/cUL Class I, Division 2, Groups A, B, C and
D
ATEX Class I, Zone 2, EEx nC IIC

EMI

FCC Part 15, CISPR (EN55022) class A

EMS

EN61000-4-2 (ESD), level 3

- 13 -

Advertising