This installation must conform with the following:

Manufacturer’s Installation instructions

Local Gas Fitting Regulations

Municipal Building Codes,

AGA Installation Code for Gas Burning Appli-

ances. (AS 5601AG 601)

S.A.A. Wiring Code

Local Electrical Regulations

Any other statutory regulations

These built-in hobs are intended to be inserted in a

benchtop cutout.
Only an authorised person should connect the appli-

ance.
Installation dimensions are shown in Fig.1

Before connecting the unit, check whether the local

connection conditions (type of gas) are compatible

with the unit’s settings. Observe any special condi-

tions imposed by local suppliers (utilities). The specifi-

cations of this cooktop are stated on the data label

located on the bottom of the cooktop base.

Installation

1

11

Depress control knob and turn anti-clockwise to ‘High

flame’ position. Hold the knob down for a few sec-

onds until the flame ignites. Keep control knob de-

pressed for a few seconds to activate the flame failure

device. If ignition fails, depress knob again and wait

for ignition. Turn anti-clockwise to set the flame to the

desired intensity.
All burners are fitted with a flame failure device which

shuts off the gas supply if the flame extinguishes for

any reason. To re-ignite, wait 30 seconds for any

unburnt gas to disperse before repeating the ignition

procedure described above.
To turn off the gas supply to a burner turn the control

knob clockwise to the ‘OFF’ position. (Refer Fig. 14)

The control knob is used to adjust the flame of the gas

burner.
‘Low flame’ graphic = lowest output
‘High flame’ graphic = highest output

Operating instructions

1. Small burner
2. Medium burner
3. Wok burner

4. Large burner
5. Medium burner
6. Control knobs

Burner ignition &

control

Preparing to install

Burner locations

13