Connection – Bosch PCL 785 FAU User Manual

Page 8

Advertising
background image

8

Electrical:

An electrical 10 amp socket needs to be within 1 m of

the hotplate to allow electrical connection. The socket

must remain accessible after installation of the appli-

ance.
Important note:
This appliance is connected to the mains (240 VAC)

by means of the connecting lead which must be fixed

to the kitchen unit to prevent it from coming into con-

tact with hot parts of the hob (or an oven installed

underneath).. When making this connection make sure

that the lead cannot come into contact with hot parts

of the hob.
Important: This appliance must be earthed.

Gas:

During the planning stage, consider the position of

supply connections.
The hob must be connected to the gas supply with

upstream connection of an isolation valve in accord-

ance with the respectively valid regulations. We rec-

ommend that the isolation valve be fitted prior to the

cooktop to enable isolation of cooktop from gas sup-

ply. The valve must be easily accessible at all times.
To find out the factory set gas type, see bottom of

cooktop next to gas connection.
Remove plastic cap from gas supply line prior to in-

stallation.
Fit regulator (N.G.) or Propane fitting (Propane) di-

rectly to the R

1

/

2

” connection as per Fig. 4 and Fig. 5.

Direction of gas flow is indicated on the rear of the

regulator.
For position of the inlet connection refer Fig.1.

Natural gas connection

Propane gas connection

Connection

Installation continued

9

It should be expressly noted that we cannot accept

any liability for direct or indirect damage caused by

wrong connection or improper installation. When

being repaired, the appliance must always be

disconnected from the mains supply; if required,

notify our customer service.

To change injectors

Request change-over injectors from our customer serv-

ice department (refer injector chart below for sizes).

Natural Gas

Propane Gas

Burner

Injector

Hourly Gas

Injector

Hourly Gas

size(mm) Consumption

size (mm) Consumption

(mm)

(MJ)

(mm)

(MJ)

Left Front

0.90

4.0

0.5

3.25

Left Rear

1.20

6.5

0.67

6.25

Centre

1.70

14.0

0.97

13.25

Right Front

1.20

6.5

0.67

6.25

Right Rear

1.60

12.0

0.85

10.0

Before conversion the cooktop must be disconnected

from the electricity and gas valves must be turned to

the OFF position.
1 Remove the trivets, burner caps and burner heads.

Refer Fig. 6

2 Change the injectors using a 7-mm socket wrench

and be sure to tighten them down properly so that

they are fully airtight. Refer Fig. 7.

3 Re-assemble the burner component parts in reverse

order.

NOTE: it is not necessary to adjust the primary air

control on these burners.

4

5

Converting the cooktop

from Nat. Gas to

Propane Gas

6

7

Advertising