Installing the phase ii cassette covers – Rockwell Automation 20D-MDI-C1 Multi-Device Interface Option Board for PowerFlex 700S Drives User Manual

Page 15

Advertising
background image

Multi-Device Interface Option Board for PowerFlex® 700S Drives

15

Step 9: Install the Phase II
Control Cassette Covers

In order to install the Phase II Control Cassette in the drive, you must first
install the covers.

Installing the Phase II Cassette Covers

Figure 11 Registration Sensor connection

Connection Examples

POWER

COMMON

12

11

10

9

8

7

6

5

4

3

2

1

Rotary Encoder +COS

Rotary Encoder DATA+ (RS485)

Rotary Encoder REGISTRATION-

Linear Sensor REGISTRATION+

Linear Sensor CLOCK+

Rotary Encoder DATA- (RS485)

Linear Sensor DATA+

Linear Sensor CLOCK-

Linear Sensor DATA-

Rotary Encoder REGISTRATION+

Linear Sensor REGISTRATION-

CHASSIS GND

MDI Feedback Option Board

17

16

15

14

13

Rotary Encoder POWER COMMON

Rotary Encoder POWER

Rotary Encoder +SIN

Rotary Encoder REFSIN

Rotary Encoder REFCOS

EXTERNAL

12 or 24 Vdc

POWER

SUPPLY

Rotary

Registration Sensor

Linear

Registration Sensor

Power

+

Common

Power

+

Common

Proper tightening torque
for reassembly is 6
lb.•in.

Installing the Side Covers

Task Description

Secure the rear cover to the cassette with three
screws.
Secure the front cover to the cassette with two
screws.

A

B

=

A

B

Advertising
This manual is related to the following products: