Step 2: Remove the Top Protective
Cover

Loosen, but do not remove, the four hexalobular screws that secure the top
protective cover to the drive, then slide the cover up and off the drive chassis.
Tightening torque is noted in the illustration for reassembly.

Step 3: Remove the Existing Fan
Loss Detection Board

1.

Loosen the screws that secure the plug-in terminal block at XE to the top
of the fan loss board and remove the terminal block.

2.

Remove the plug-in terminal block at XF from the fan loss board.

3.

Remove the plug-in terminal block at XC from the fan loss board.

4.

Disconnect the ground wire from connector PE.

5.

Remove the four hexalobular screws that secure the fan loss board to the
insulator and remove the board. Tightening torque is noted in the
illustration for reassembly.

Top protective cover

Tool size: T15
1.5 N•m (13 lb•in)

=

Fan Loss Detection board

V2

V1

C1

PE

XF

XC

XE

K1

Tool size: T25
1.0…1.2 N•m
(9…10.5 lb•in)

Advertising