What you need to do, Step 1: remove power – Rockwell Automation 23P PowerFlex DC Stand-Alone Regulator (SAR) Bimetal Thermostat User Manual
Page 2
 
2
Rockwell Automation Publication 23P-IN007A-EN-P - June 2011
What You Need to Do
The list below is an overview of the steps needed to remove and replace the 
bimetal thermostat. See each step for detailed procedures.
1.
2.
3.
Remove the Control Circuit Board
4.
Remove the Power Interface Circuit Board and Switching Power Supply 
Circuit Board
5.
Remove the Field Circuit Board
6.
7.
Install the New Bimental Thermostat and Reassemble the SAR
8.
Step 1: Remove Power
Remove and lock-out all incoming power to the SAR.
IMPORTANT
The SAR has many different cables, wires, and plugs with different 
connections and routing. For ease of reassembly:
•
Make note of cable and wire routing between and within the different 
circuit boards.
•
Label connectors and plugs with the name of the connection and 
circuit board from where it was disconnected.
ATTENTION: Remove power before making or breaking cable 
connections. When you remove or insert a cable connector with power 
applied, an electrical arc may occur. An electrical arc can cause 
personal injury or property damage by:
•
sending an erroneous signal to your system’s field devices, causing 
unintended machine motion
•
causing an explosion in a hazardous environment
Electrical arcing causes excessive wear to contacts on both the module 
and its mating connector. Worn contacts may create electrical resistance.
L1
L2
L3
O
I