Special Functions

Remote Teach

1. Enter teach mode by pressing SET for three seconds until the

green LED turns off and the yellow channel one LED turns on.

2. Press

X until all three yellow channel (CH1, CH2, CH3) LEDs turn

on.

3. Press SET for three seconds to confirm.

4. Press

X until the middle red tolerance LED is on.

5. Press SET for three seconds to confirm.

6. Press

X until all the red (tolerance) LEDs turn off.

7. Press SET for three seconds.

8. The sensor is now in Remote Teach mode. When entering remote

teach mode the output Q3 becomes a teach input. Connect this
pin to +V/+DC to teach a new color with medium tolerance on
channel one. In Remote Teach mode, output Q2 is a teach
acknowledgment. When the sensor is successfully taught a color,
output Q2 will turn on for 50 mS to confirm a successful teach.

Tol.

Tol.

Pulse Stretching

1. Enter teach mode by pressing SET for three seconds until the

green LED turns off and the channel one yellow LED turns on.

2. Press

X until all three yellow channel (CH1, CH2, CH3) LEDs turn

on.

3. Press SET for three seconds to confirm.

4. Press

X until the red low tolerance LED turns on.

5. Press SET for three seconds to confirm.

6. Press

X until all the red (tolerance) LEDs turn off.

7. Press SET for three seconds.

8. The sensor is now ready to operate. (Yellow channel LED is on

when target is present.) A color match on any channel will result
in an output signal at least 50 mS in length.

Default Factory Settings

To configure the sensor to the manufacturer's default settings:

1. Enter teach mode by pressing SET for three seconds until the

green LED turns off and the channel one yellow LED turns on.

2. Press

X until all three yellow channel (CH1, CH2, CH3) LEDs turn

on.

3. Press SET for three seconds to confirm.

4. Press

X until the (CH1 & CH2) red tolerance LED turns on.

5. Press SET for three seconds to confirm until the green power

LED turns on.

6. Press

X until all the red (tolerance) LEDs turn off.

7. Press SET for three seconds until the green power LED turns on.

The sensor has now been set to manufacturer's default settings.
All special functions are de-activated and previous color settings
are reset.

Tol.

Tol.

Cordsets and Accessories

Publication: 10000007742

[068-14169]

January 2008

Printed in USA

Description

Cat. No.

DC Micro Style QD Cordset, 8-Pin

889D-F8AB-2

Mounting Bracket. Used for Laser Sensors

45CPD, 45BRD

45BPD-BKT1

Protective Mounting Bracket. Used for

Laser Sensors 45CPD, 45BRD

45BPD-BKT2