Wiring diagrams, 3approximate dimensions [mm (in.), Downstream connection (discharge end) – Rockwell Automation 44N Zone Control Photoelectric Sensors User Manual

Page 3: Female, Male, Upstream downstream

Advertising
background image

3

Approximate Dimensions [mm (in.)]

55.62 (2.19)

74.93

(2.950) Ref

31.75

(1.250)

40 (1.575)

32.66 (1.286)

M30 x 1.5 external

thread 1/2 in. NPSM

internal thread

5.21 (0.205) x

8.13 (0.320)

Slot, 2 Places

5.46 (0.215)

15.87 (0.625)

41.91

(1.65)

30.35

(1.195)

–

103.63 (4.08)

Max. Travel

—

—

– 304.88 mm (12 in.) cable on 44NSP--2JPBD--Z01. Female right angle pico (M8) QD on a

533.4

mm (21 in.) cable on 44NSP--2JPBD--Z02 and 44NSP--2JPBD--Z03.

— Refer to page 1 for downstream and upstream cable lengths.

ZONE 4

ZONE 3

ZONE 2

ZONE 1

valve

P4

P3

P2

P1

Direction of Product Flow

valve

valve

valve

Upstream Connection

Downstream Connection

Wiring Diagrams

Female

(Pin 1)

Blu

e

( + )

( -- )

Male

(Pin 2)
(Pin 4)
(Pin 3)

(Pin 1)
(Pin 2)
(Pin 4)
(Pin 3)

Slug
Singulation

( + )

( -- )

Slug

Singulation

2

1

Bro

wn

˜

Upstream

Downstream

Output load 30V DC

100 mA, PNP

˜ Product comes with 22 AWG cable.

3

2

4

1

3

4

1

2

5

Downstream Connection (Discharge End)

For Singulation Release:

To activate the singulation release signal connect pin 4 (black
wire using an 889D--F4BC--2 cable) to +24V DC. The
discharge zone will singulate as long as the singulation
release signal is active.

For Slug Release:

To activate the slug release signal connect pin 2 (white wire
using an 889D--F4BC--2 cable) to +24V DC. All the zones will
drive simultaneously without singulating (separating) the
boxes.

Upstream Connection (Infeed End)

The 44N Zone Control sensor allows the user to monitor the
status of the infeed zone by using an 889D--M4BC--2 male
cordset connected to the upstream connection of the infeed
sensor.

The black wire of the 889D--M4BC--2 cordset provides this
signal. A voltage signal indicates that there is no object
blocking the infeed zone. A 0V DC signal indicates that the
infeed sensor is blocked.

The upstream connection output current is limited by a 3 k

resistor, which would allow the sensor to drive certain I/O
cards. Rockwell Automation recommends the following I/O
cards for reliable output detection.

1769--IB16I
1756--IB32
1756--IB16
1769--1Q32
1769--1Q16

Advertising