Step 2, Mount the drive, Lifting – Rockwell Automation 20L PowerFlex 700L Frame 1X Liquid-Cooled Adjustable Frequency AC Drive User Manual
Page 9

PowerFlex 700L Frame 1X Drive Installation Instructions – Publication 20L-IN013A-EN-P – June 2009
9
Refer to
for lifting information.
Figure 2
Drive Weight and Lifting Orientation
Step 2
Mount the Drive
Lifting
!
ATTENTION: To guard against possible personal injury and/or
equipment damage...
• Do Not allow any part of the drive or lifting mechanism to
make contact with electrically charged conductors or
components.
• At no time should a person or their limbs be directly
underneath the items being lifted.
• Do not subject the load to high rates of acceleration or
deceleration.
• Inspect all lifting hardware for proper attachment before
lifting drive unit.
Drive Weight:
44.5 kg (98 lbs.)
Angle must
be less
than 45°
STRAP DETAIL
Loop strap over handle cross-
member and under handle as
shown. Typical 4 places.
U
T1
V
T2
W
T3
OUT
PUT
NOTE: Sling capacity is typically