5

DistanceĊm (ft)

Typical

Specified

1

(3.3 ft)

0

0.5

(1.6 ft)

1.5

(4.9 ft)

2

(6.6 ft)

20

30

40

50

60

70

80

90

0

10

Minimum Object SizeĊmm

Minimum Detectable Object Size

Retroreflective Mode

Transmitter

Receiver

Power Indicator

(Green)

Dark Indicator (Orange)

Lights when the beam is interrupted

Light Status Indicator (Green/Orange)

Green: Stable light condition (>1.5 x gain).

Orange: Misaligned or interrupted beam.

Retroreflective/Diffuse

Output Indicator (Orange)

Power Indicator (Green)

Blinks orange & green during power up sensitivity

adjustment

Operating Indicator

Job Indicator & Warning Indicator
The green job indicator LED is on when the input to the PVA is on. The output signal is turned on when the target is present
(when in Dark On or Normally Open mode). For example, when the operator’s hand is in the bin. The red warning indicator is on
when the target is present and the input is off.

OFF

ON

OFF

Input

Green Job Indicator (determined by input)

Target Present (operator hand in bin)

Output (determined by target present)

Red Warning Indicator

ON

ON

ON

ON

ON

ON

Light Margin and Operating Indicators (transmitted beam receiver only)

Dark Indicator

(Orange)

Light status

Indicator

x1.5

x1.0

Operating Level

Stable light

area
Unstable light

area

Dark area

Light

Orange

Green

Light

Orange

Note: Use a dry, soft cloth for cleaning the lens and case. Lightly wipe it off. Never use solvents such as thinner.

Advertising