2sensor selection, Output and stability indicators, Operation selector switch – Rockwell Automation 45FVL Digital Self-Teaching Fiber Optic User Manual

Page 2: Two adjustment buttons, Mounting the sensor

Advertising
background image

2

Sensor Selection

Output Characteristics

Catalog Number

Operating

Voltage

Current

Consumption

Type

Max Load

Current

Max Leakage

Current

Response

Time

LED

Cable

Pico

Power Bus

(QD required)

Red

45FVL-2LHE-A2

45FVL-2LHE-P4

45FVL-2LHE-C4 Ê

50ma or Less

PNP

Green

45FVL-3LHE-A2

45FVL-3LHE-P4

45FVL-3LHE-C4 Ê

50ma or Less

PNP

Blue

45FVL-6LHE-A2

45FVL-6LHE-P4

45FVL-6LHE-C4 Ê

12-24V DC

Output: 100ma

0 5ma

600µs

White

45FVL-5LHE-A2

45FVL-5LHE-P4

45FVL-5LHE-C4 Ê

C

+/- 10%

Output: 100ma

Stability: 50ma

0.5ma

600µs

Red

45FVL-2LGE-A2

45FVL-2LGE-P4

45FVL-2LGE-C4 Ê

+/ 10%

39ma or Less

NPN

Green

45FVL-3LGE-A2

45FVL-3LGE-P4

45FVL-3LGE-C4 Ê

39ma or Less

NPN

Blue

45FVL-6LGE-A2

45FVL-6LGE-P4

45FVL-6LGE-C4 Ê

White

45FVL-5LGE-A2

45FVL-5LGE-P4

45FVL-5LGE-C4 К

К

PowerBus master/3 conductor QD = 45F–A3C–A2. PowerBus slave/1 conductor QD = 45F–A1C–A2

Output and Stability Indicators

Two LEDs (green and orange) indicate a variety of conditions
to facilitate set-up and troubleshooting. The function of each is
described in the table below. Relevant output and stability
data are also shown.

LED

State

Condition

Green

OFF

ON

Unstable light signal

Stable light signal

Orange

OFF

ON

Output OFF

Output ON

Operation Indicator and Stability Indicator

Light on operation

Stable range level

On level

Off level

Unstable range level

Unstable range

Operation

Indicator

Output

Light level

Stability

Indicator

On

On

On

On

On

Unstable range

Stable range

(light interrupted)

Stable range

(light interrupted)

Stable range

(light on)

Unstable range

Dark on operation

Stable range level

Off level

On level

Unstable range level

Unstable range

Operation

Indicator

Output

Stability

Indicator

On

On

On

On

On

Unstable range

Stable range

(light interrupted)

Stable range

(light interrupted)

Stable range

(light on)

Unstable range

Light level

Operation Selector Switch

When the selector switch is in the RUN position (see following
example), the sensor will function normally, and all settings
are locked from adjustment. The SET position unlocks the
sensor’s settings, allowing the user to either adjust the sensor
manually, or use the self-teach functionality. When
adjustments are complete, return the switch to the RUN
position (settings become locked). If a manual sensitivity
adjustment is required a user can unlock this setting by
(quickly) switching from RUN to SET to RUN. The sensor will
display a flashing “S” on the LCD display, and the user can
now adjust the sensitivity setting. The sensor will automatically
return to the locked condition 10 seconds after sensitivity
adjustment is complete.

Locking

Two Adjustment Buttons

The red button is used to teach the sensor, change the
frequency and to increase the sensitivity.

The black button is used to change the operating mode,
indication mode and to decrease sensitivity.

Both buttons are inactive in the RUN mode.

Mounting the Sensor

How to Attach Sensor to DIN Rail

Attach front hook of the photoelectric
sensor onto rail (or Mounting bracket)
and press rear end of sensor down
until unit snaps into place.

How to Detach Sensor from DIN Rail

Pushing the sensor unit forward,
pull up on the front of the sensor
until the front hook is detached.
Remove sensor.

Side Mounting Sensor with Bracket

Fasten mounting bracket assembly
using M3 screws. Tightening torque is
0.8Nm max. Attach front hook of the
photoelectric sensor onto mounting
bracket and press rear end of sensor
down until unit snaps into place.