Rockwell Automation 20L PowerFlex 700L Frame 2 Common Mode Choke Kit (SK-L1-CHK2-F2) User Manual
Page 3

PowerFlex® 700L Frame 2 Common Mode Choke Kit
3
Figure 1 Power Wiring Connections Through Choke Assemblies to the Drive
Figure 2 Motor Output Power Leads through Clamp Assembly
8. Mount the choke assembly for the AC input power to the drive on a metal
surface near the bottom of the drive using M8 hardware. Leave sufficient
clearance between the choke assembly and the drive terminals to allow
access to the terminals and provide proper bend radius for the leads.
9. Run the AC input power leads to the drive straight through the choke
assembly (
) and terminate at the R/L1, S/L2, and T/L3 drive
terminals. Note: When using two cables for each phase, pass each cable
through a choke assembly.
AC Input
POWER
STS
PORT
MOD
NET A
NET B
Motor
Clamp
Assemblies
PE
W/T3
V/T2
U/T1
W/T3
V/T2
U/T1
Choke
Assemblies
T/L3
S/L2
R/L1
AC Input
T/L3
S/L2
R/L1
Ground
Motor Frame
Cable To Motor
W (T3), V (T2), and U (T1)
Cable To Motor
W (T3), V (T2), and U (T1)
From Drive W (T3)
From Drive V (T2)
From Drive U (T1)
From Drive W (T3)