2dimensions—mm (inches), Installing sensor in a chemical environment – Rockwell Automation 42KF-T1JNTN-A3_D1KNTH-A3 PHOTOSWITCH User Manual

Page 2

Advertising
background image

2

Dimensions—mm (inches)

16.0

(0.63)

Dia. 7.0 (0.28)

13.4

(0.53)

13.0

(0.51)

24.5

(0.96)

20.0

(0.79)

31.0

(1.22)

7.0

(0.28)

Dia. 2--4.2

(0.08--0.17)

Dia. 5.0 (0.20)

7.0

(0.28)

Optional Sensitivity Adjustment Module (61--6736, 61--6737)

Brown: 12--24V DC

Sensor Side

Cable 4C

58.0 (2.28)

11.0

(0.43)

9.6

(0.38)

Brown: 12--24V DC

Sensor

Receiver

Side

}

Blue: 0V

Black: Output

Orange: Ext Pot

Blue: 0V

Black: Output

Sensitivity

Adjustment

LO/DO Switch

Output Side

Cable 3C

Installing Sensor in a Chemical Environment

The PFA tube is 2 meters (6.56 feet) in length. When installed

in a chemical environment a PFA conduit must be used at the

partition from the chemical environment to the normal

atmosphere. At least 152.4mm (6in) of PFA tube should

remain in the normal atmosphere.

Chemical

Environmental

Notes

S

Do NOT use in hazardoud locations that are explosive.

S

Avoid installing sensor near high frequency equipment, such as 4F flourescent lighting.

S

Do NOT extend the cable length between the optional sensitivity adjustment module and the sensor.

PFA Sensor

PFA

Tube

Conduit

Normal

Atmosphere

Partition

Sensor cable

Advertising