OPERATING MARGIN
1. The operating margin is parenthesis are for diffuse white surfaces

that fill the control’s field of view.

2. 6.1% and 2.6% designate dark colored surfaces having diffuse re-

flectance of 6.1% and 2.6% respectively compared to diffuse white.

3. The 2.6% surface is Krylon # 1602 Ultra flat black.

TYPICAL RESPONSE CURVE

OPE

RA

TING

M

AR

GIN

OPERATING DISTANCE

100X

10X

.1”

(.254cm)

1000x

1X

.3”

(.762cm)

.5”

(1.27cm)

.8”

(2.032cm)

2”

(5.08cm)

4”

(10.16cm)

6”

(15.24cm)

8”

(20.3cm)

10”

(25cm)

12”

(30cm)

SUPPRESSION SET FOR 8(20.3CM)

TYPICAL SUPPRESSION CURVE

DIST

AN

CE

TO

SEN

SE

D

O

BJ

EC

T

DISTANCE TO BACKGROUND OBJECT

14

(35.5cm)

12

(30.5cm)

10

(25.4cm)

8

(20.3cm)

6

(15.2cm)

4

(10.1cm)

2

(5.08cm)

0

0

2

(5.08cm)

4

(10.1cm)

6

(15.2cm)

8

(20.3cm)

10

(25.4cm)

12

(30.5cm)

14

(35.5cm)

(O

PER
AT

IN

G

M

AR

GI

N)

M

-16

(O

PER
AT

IN

G

M

AR

G

IN)

M

-3

8

WHITE PAPER

6.1%

2.6%

WIRING

All external wiring should conform to the National Electric Code and

applicable local codes. See wiring diagrams for external connections.

L1

Black

L1

NC

C

Yellow (Common)

Orange

NO

Blue

Load

L2

White

L2

E--M RELAY

OUTPUT

TERMINAL BASE

42MTB-5000 120VAC

42MTB-5001 240VAC

42MTB-5002 48VAC/DC

42MTB-5003 24VAC

TYPICAL WIRING DIAGRAMS

L1

Black

L1

NC

C

Yellow (Common)

Orange

NO

Blue

Load

L2

White

L2

SOLID STATE

RELAY OUTPUT

TERMINAL BASE

42MTB-5000 120VAC

42MTB-5001 240VAC

42MTB-5002 48VAC/DC

42MTB-5003 24VAC

+

(+)

3

2

1

TTL Logic

--

Black

(--)

TERMINAL BASE

Programmable

Controller

DC Interface

10--30VDC

+5VDC

42MTB-5004

with 8-593

Blue

Grey

Orange

Red

Advertising