3short-circuit protection, Wiring diagrams – Rockwell Automation 42EF RightSight Photoelectric Sensors User Manual

Page 3

Advertising
background image

3

Short-Circuit Protection

RightSight photoelectric sensors provide short-circuit protection (SCP) on the output

leads. This feature is intended to protect the sensor from damage in the event that the

output load is shorted to ground. If this condition does occur, the SCP will activate and

the orange LED wil flash until the source is removed (power must be reset for AC/DC

models). The SCP limits are set to 100 mA over the entire voltage range for both DC

and AC/DC models.

Wiring Diagrams

Cable

Quick-Disconnect

DC Wiring for 42EF- _ _ _F_ _- _ _ Models

Cable

Quick-Disconnect

1

2

3

Red/White

Red

Red/Black

Blue

Black

Brown

AC Wiring for 42EF- _ _ _C_ _- _ _ Models

21.6--264V AC/DC Sensors

DC Micro

DC Micro

Blue

Black

White

Brown

Cable

Quick-Disconnect

Cable

Quick-Disconnect

Cable

Quick-Disconnect

Models with PNP Outputs

Models with NPN Outputs

Models with Dual NPN and PNP Outputs

10.8--30V DC Sensors

+

+

+

+

+

+

+

+

+

+

Load

Load

Blue

Black

White

Brown

Load

Load

1
2

4

3

DC Micro

1

2

4

3

Blue

Black

White

Brown

Load

Load

Blue

Black

White

Brown

Load

Load

Blue

Black
White

Brown

Load

Load

Blue

Black
White

Brown

Load

Load

1

2

4

3

1

2

4

3

1

2

4

3

1

2

4

3

Blue

Black

Brown

Load

L2

L1

L2

L1

1

2

3

Red/White

Red

Red/Black

Load

1

2

3

Load

Blue

Black

Brown

L2

L1

Load

1

2

3

Red/White

Red

Red/Black

L2

L1

AC Wiring for 42EF- _ _ _F_ _- _ _ Models

Cable

Quick-Disconnect

DC Wiring for 42EF- _ _ _C_ _- _ _ Models

Load

Load

4

1

2

3

4

Blue

Black

Brown

Load

1

2

3

Red/White

Red

Red/Black

Load

Transmitted Beam Source

AC and DC Wiring

L2/--

L1/+

Blue

Brown

1

2

Red/White

Red/Black

L2/--

L1/+

Note: All wire colors on quick-disconnect models shown refer to Allen-Bradley cordsets.

Advertising