2. Unsolder the wire leads from all resistor terminals. Retain the wires for
reuse.
3. Remove the two hexalobular screws and washers that secure each of the
snubber resistors to standoffs on the back wall of the drive chassis and
remove the resistors.
Step 5: Install the New
Snubber Resistors
• Install the snubber resistors in the reverse order of removal as detailed in
Remove the Existing Snubber Resistors on page 8
.
Step 6: Install the SCR
Module Leg Assemblies
• Install the SCR module leg assemblies in the reverse order of removal as
Remove the SCR Module Leg Assemblies on page 4
– Tightening torque for the SCR module leg assemblies is 4.5…5.0 N•m
(40.0…44.4 lb•in).
– Tightening torque for the SCR module input and output terminals to the
fuse terminals and DC output bus bars is 45 N•m (398 lb•in).
Remove screws and washers