background image

56RF-IN013A-EN-P

September 2012

Printed in USA

LED Illumination Pattern

Connector Pinout

Frequently Asked Questions

Reference the product manuals for more specific installation
and configuration information. Manuals are available at

www.ab.com/rfid

.

LED Display

Content

Module Status
LED

Green light

Power ON

No illumination

No power

Read/Write
LED

Green light

Normal operation

Solid green

Communicating

Solid amber

Sensing tag

Flashing red

Communication error

Pin

Signal

1

24V DC

2

Data +

3

GND

4

Data –

Installation of Allen-Bradley products should
be in accordance with local and/or national
codes. Servicing energized industrial control
equipment can be hazardous if not in
accordance to recommended safety
procedures.

4

3

1

2

IMPORTANT

73 (2.9)

63 (2.5)

12.2

(0.48)

35.8 (1.41)

7

(0.28)

M30x1.5

M12x1

28

(1.10)

dia

28

(1.10)

dia

Read/Write

Status LED

Module
Status LED

Approximate Dimensions [mm (in.)]

Dimensions are not intended to be used for installation purposes.

Torque mounting nuts to 33.9N-m (25 ft-lb).

Nuts and washers included

Nut

Washer

Tightening Torque

Mounting Brackets

Replacement Nuts and Washers

Description Cat.

No.

Swivel/tilt style

60-2439

Right angle style

871A-BRN30

Description Cat.

No.

Nut 871C-N4

Washer 871A-LWN30

Advertising