Rockwell Automation 20P PowerFlex DC Drive - Frame B AC Line Snubber Board and High Wattage Resistors User Manual

Page 11

Advertising
background image

PowerFlex® DC Drive - Frame B AC Line Snubber Board and High Wattage Resistors

11

11. Remove the appropriate gate leads (see

Figure 1 on page 6

for location):

For non-regenerative drives, remove each pair of (orange and yellow)

gate lead cables from connectors KG01…KG06 and push each lead
through the appropriate opening in the board.

For regenerative drive, remove each pair of (orange and yellow) gate

lead cables from connectors KG01…KG06 and KG1…KG6 and push
each lead through the appropriate opening in the board.

Important: Remove the gate leads by grasping the connector and

pulling up. DO NOT pull the gate leads off by pulling on
the wires.

For non-regenerative
drives, remove six gate
leads and route
through openings in
board

For regenerative
drives, remove 12 gate
leads and route
through openings in
board