Rockwell Automation 56RF Rectangular 80x90 mm Transceiver Installation Instructions User Manual

Important: save these instructions for future use

Advertising
background image

Installation and Operating Instructions

Bulletin 56RF RFID Rectangular 80 x 90 mm Transceiver

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

This publication does not include all specifications, dimensions, or any special installation considerations.

Refer to the product catalog pages for additional information.

Description

The rectangular transceiver is the largest transceiver in the
Allen Bradley high frequency 13.56 MHz RFID family and
measures 80 x 90 mm. This transceiver is ISO 15693
compliant and can read/write ICODE tags SLI and SL2,
allowing infinite tag configuration options from various
manufacturers. Built-in LEDs allow for quick visual diagnosis
of module status and read/write status.

Rectangular transceivers are recommended for high speed/
high performance applications because of their large sensing
range. Transceivers can be mounted up to 300 ft (91.4 m)
away from the interface module, and tags are readable from
distances up to 6.6 in. (168 mm). This transceiver has an
enclosure rating of IP67 and is designed to withstand harsh
industrial environments.

Features

• 13.56 MHz high frequency RFID solution
• ICODE ISO 15693/ISO 18000-3 M1 Compliant
• Read/write speeds up to 625 B/s
• Transceivers can be mounted up to 300 ft (91.4 m) away

from interface modules

• Built-in LEDs for diagnostics
• Universal mounting
• Reliable performance in harsh environments

Typical Applications

• Asset tracking
• Data acquisition
• Product handling
• Tool management
• Automotive
• Food and pharmaceutical
• Security and entrance

Minimum Distance Between Transceivers

Minimum Distance from Surrounding Metal

Min. 600 mm

Metal

Min.
50 mm

Specifications

➊ No condensation
➋ Range reference for a 50 mm diameter tag

Product Selection

Scanning Area ➌

Note: Ideal tag distance for maximum performance is 70…130 mm.

➌ Referenced for a 50 mm disc tag.

General

Enclosure Rating

IP67

Operating Temperature

-25…+70 °C (-13…+158 °F)

Storage Temperature

-40…+85 °C (-40…+185 °F)

Operating Humidity ➊

35…95% RH

Storage Humidity ➊

25…85% RH

Vibration

10 g at 10…500 Hz

Shock Resistance

50 g

Recommended Sensing Distance ➋

4 in. (102 mm)

Max. Sensing Distance ➋

6.6 in. (168 mm)

Max. Distance from Interface Module

300 ft (91.4 m)

Compliance

CE, cULus, C-Tick

Type of Equipment

Industrial control

Electrical
Supply Voltage

24V DC (-20…+10%)

Max. Current Consumption

100 mA

Tag Compatibility

ICODE tags SLI, SL2
ISO 15693 / ISO 18000-3 M1

Connector

M12 4-pin male

Communication Systems

Half duplex communication system
(RS-485)

Baud Rate (Host)

9600 / 19200 / 38400 / 115200 bps

Frequency

13.56 MHz

Baud Rate (Tag)

26.48 kbit/s

Data Length

8-bit

Description

Cat. No.

Rectangular 80 x 90 Transceiver

56RF-TR-8090

Misalignment

Sensing Distance [mm]

0

50

100

150

Side Lobe

Side Lobe

OFF

OFF

OFF

0

-150

-100

-50

50

100

150

130

70

ON

Advertising