1

Installation Instructions

PHOTOSWITCH

Bulletin 42FT SelfĆTeach Fiber Optic

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Description

The 42FT is a compact, DIN Rail Mount Fiber Optic
Photoelectric sensor with sophisticated part detection,
diagnostic, and self-teach capabilities.

Five LED indicators provide diagnostic and alignment
information. A dynamic diagnostic output signals when margin
levels are below a predetermined threshold for seven
successive detections.

The self-teach capability allows the Bulletin 42FT to determine
an optimum sensitivity and hysteresis setting for a specific
application. The remote lockout feature can be used to help
prevent unauthorized changes to these adjustments. A switch
selectable 50ms off-delay (“pulse stretcher”) is useful in high
speed applications where the output pulse must be lengthened
to allow time for the machine logic to respond.

42FT sensors are designed for DIN rail mounting. For
installation convenience, a steel mounting bracket is supplied
for separate mounting.

42FT sensors are designed for use with 2.2mm diameter
plastic fiber optic cables. An adaptor is supplied with the
sensor to use 1.25mm diameter plastic fiber optic cables. Fiber
optic cables are held in place by a rotating collar. No tools are
required to attach or remove fiber optic cables. Special glass
fiber optic cables are also available. Over 40 compatible
standard plastic and glass fiber optic cables are available,
please refer to page 1–232 of the C112 Sensor catalog.

Features

S

Pico quick-disconnect available

S

(5) LED indicators: 0.8X to 1.6X margin and output

S

Manual or Self-Teach sensitivity adjustment

S

Manual or Self-Teach hysteresis adjustment

S

Stability output

S

Visible red, green, or blue light sources

S

Selectable light or dark operate

Features (continued)

S

Selectable 50ms off-delay output (pulse stretcher)

S

Can be DIN rail mounted or separately mounted

S

No tools required to attach or remove Fiber Optic cables

General Specifications

Output Protection Short circuit, Reverse polarity, False pulse, Transient noise

Housing Materials ABS resin, polycarbonate cover

Cable Construction 2m (6.5ft) 500V PVC jacketed 24AWG multiĆconductor

cable

Supplied

Accessories

Adjustment screwdriver, 1.25mm diameter fiber optic cable

adaptors

Operating

Environment

NEMA 1, 4X, 12, 13 and IP66 (IEC 529) (Mounting bracket

not NEMA 4X)

Vibration 10-55Hz, 1mm amplitude, Meets or exceeds IEC 947-5-2

Shock 30G, Meets or exceeds IEC 947-5-2

Ambient

Temperature

-25

°

C to +55

°

C (-13

°

F to +131

°

F)

Relative

Humidity

85%

Approvals UL listed and CSA certified, and CE marked for applicable

directives

Emitter LED Visible red 660nm: 42FT-F2LNA-XX

Visible green 565nm: 42FT-F3LNA-XX

Visible blue 450nm: 42FT-F6LNA-XX

Connections

Cable:

5Ćconductor PVC

3Ćpin pico quickĆ

jacketed cable 2m (6.5ft)disconnect style
42FT-F2LNA-A2

42FT-F2LNA-Y3

42FT-F2LPA-A2

42FT-F2LPA-Y3

42FT-F3LNA-A2

42FT-F3LNA-Y3

42FT-F3LPA-A2

42FT-F3LPA-Y3

42FT-F6LNA-A2

42FT-F6LNA-Y3

42FT-F6LPA-A2

42FT-F6LPA-Y3

Wiring

Brown: 12V-24V DC
Black: Output

Pink: External Set

Orange: Stability Output

Blue: -DC

Black: Output
Orange: Stability Output

Pink: External Set

Brown: 12V-24V DC

Cable

Blue: -DC

Remote Self

Teach Activate

Cable

Remote Self

Teach Activate

Load

Load

Load

Load

Brown

Black

Blue

1

3

4

Brown

Black
Blue

1

3

4

Pic

o

1 3

4

NPN Output

Cable

QuickĆDisconnect

PNP Output

Note:

Details regarding connection of Allen-Bradley Bulletin 42FT photoelectric sensors to Allen-Bradley Programmable Controllers
can be found in publication 42-2.0.