Rockwell Automation 194RF-xxxx Front-Operating Disconnect and Handle w/ Interlock Kit User Manual

E doc

Advertising
background image

41053-253

G. Ushakow

N/A

N/A

N/A

41053

1002489

1

1003618

2

9-15-03

M.A. Jutz

9-15-03

K. Hecht

9-15-03

1

7

BULLETIN 194RF NFPA 79 COMPLIANT FUSED

AND NON-FUSED DISCONNECT SWITCH INSTRUCTION SHEET

CAT 194RF-30R1, -30R2, -60R1, -60R2 Kits CAT 194RF-NJ030R14, -NJ030R14E, -NJ030R24,

-NJ030R24E, -NJ060R14, -NJ060R14E, -NJ060R24, -NJ060R24E, -NN030R14, -NN030R14E,

-NN030R24, -NN030R24E, -NN060R14, NN060R14E, -NN060R24, -NN060R24E, -NC030R14,

-NC030R14E, NC030R24, -NC030R24E

REVISION

AUTHORIZATION

DIMENSIONS APPLY BEFORE

SURFACE TREATMENT

H

A

B

C

D

E

F

G

(DIMENSIONS IN INCHES)

TOLERANCES UNLESS

OTHERWISE SPECIFIED

REFERENCE

SHEET

OF

DWG.

B

DR.

CHKD.

APPD.

DATE

DATE

DATE

±

±
±

ANGLES:

.XXX:

.XX:

LOCATION : MILWAUKEE,

WISCONSIN

U.S.A.

SIZE

1

2

3

4

5

6

7

8

E DOC

CAT.

L1 L2

L3

L1 L2

L3

L1 L2

L3

U.L. RECOGNIZED ACCESSORIES

OTHER ACCESORIES

-HS4
-HS1E
-HS4E

OPERATING HANDLE

194R-R1
-R2

OPERATING SHAFT

194R-FCA2

194R-FCJ60

194R-LNC1
-LNC2

TERMINAL SHIELD

194R-HAIRPIN

COTTER PIN

194R-AA

AUXILIARY CONTACT ADAPTER

195-GA01
-GA10
-GA11
-GA02
-GA20

CAT.

FUSE COVER

CAT.

U.L. LISTED SWITCHES

DIMENSION REFERENCE

CIRCUIT

194R-NC030P3

194R-NJ060P3

A1

B1

194R-NN030P3

194R-NN060P3

A2

B2

OTHER SWITCHES

CIRCUIT

194R-NA100P3

194R-NA200P3

194R-NA300P3

A1

A1

B1

CAT.

DIMENSION REFERENCE

194RF-R1TUBE

R1 SIZE TUBE GUARD

194RF-R2TUBE

R2 SIZE TUBE GUARD

194RF-NFPAHANDLE

NFPA INTERNAL HANDLE

194RF-LATCHARM

BRACKET LATCHARM

194RF-R1PAIR

R1 and TUBE GUARD PAIR

194RF-R2PAIR

R2 and TUBE GUARD PAIR

194RF-ENCLOSURETAG

194RF ENCLOSURE TAG

194RF-3412ENCLOSURE 194RF PAINTED STEEL TYPE 3/4/12 ENCLOSURE

194R-NJ030P3

A1

AUXILIARY CONTACT

194R-HS1

ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
Install in suitable enclosure. Keep free from contaminants.

Fuse cover must be installed for safe operation.

Check that disconnect switch is in OFF position before assembly.

(

Cat 194RF-30R1, -30R2, -60R1, -60R2) Kits (Cat 194RF-NJ030R14, -NJ030R14E, -NJ030R24,

-NJ030R24E, -NJ060R14, -NJ060R14E, -NJ060R24, -NJ060R24E, -NN030R14, -NN030R14E,
-NN030R24, -NN030R24E, -NN060R14, NN060R14E, -NN060R24, -NN060R24E, -NC030R14,
-NC030R14E, NC030R24, -NC030R24E)

NFPA 79 Compliant Front-Operating Disconnect And Handle With Interlock Kit

THIS DRAWING IS THE PROPERTY OF

ROCKWELL INTERNATIONAL CORPORATION

OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,

USED OR DISCLOSED FOR ANY PURPOSE

EXCEPT AS AUTHORIZED IN WRITING BY

ROCKWELL INTERNATIONAL CORPORATION

41053-253-01 (2)

Printed in U.S.A.