Rockwell Automation 440P Small Metal Safety Position Switches User Manual

Rockwell Automation Equipment

Advertising
background image

Installation and Operating Instructions

Bulletin 440P Small Metal Safety Position Switches

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

This publication does not include all specifications, dimensions, or any special installation

considerations. Refer to the product catalog pages for additional information.

General Data

• Safety contacts: 1 N.C.
• Auxiliary contacts: 1 N.O.
• Enclosure rating:

• NEMA 1
• IP66, IP67, IP69K

• Rugged die cast housing
• 2 m prewired cable
• Compact profile for access limited installation

Principles, Standards, and Implementation

Before installation in a safety application, perform a risk
assessment to determine whether the specifications of this
device are suitable for foreseeable operational and
environmental characteristics of the machine which is to be
controlled. Only the normally closed set of contacts are
considered safety contacts. When deploying these limit
switches in a safety system application, all applicable
standards for application should be followed. Operating
specifications must be followed. The actuator must be placed
beyond the point where Direct Opening Action occurs.
Do not use these devices to directly control a motor.

Specifications

Safety Ratings

Standards

EN 954-1, ISO 13849-1,
IEC/EN 60204-1, NFPA 79, EN 1088,
ISO 14119, IEC/EN 60947-5-1,
ANSI B11.19 AS 4024.1

Safety Classification

Cat. 1 Device per EN 954-1 Dual channel
limit switch suitable for Cat. 3 or 4
systems

Certifications

cULus Listed, TÜV and CE Marked for all
applicable directives

Functional Safety Data

B10d: 2x10

6

operations

ATTENTION

To avoid electrical shock and unintended operation of
equipment, disconnect all power to the limit switch and
the controlled equipment before proceeding with any
repair or adjustment of the limit switch.

Installation of Allen-Bradley Guardmaster products

should be in accordance with local and/or national

codes. Servicing energized industrial control equipment

can be hazardous if not in accordance with

recommended safety procedures.

Contact Ratings

Outputs

Safety Contacts

1 N.C. snap acting

Auxiliary Contacts

1 N.O. snap acting

Thermal Current (/

lth

)

10 A

Rated Insulation Voltage (ui)

300 AC

Short Circuit Protection

10 A max. fast acting fuse IEC 269 type
gG or equivalent

Maximum AC Contact Rating Per Pole (50/60 hz) Same Polarity

NEMA Rating

Designation

Max.

Voltage

Amperes

Continuous

Carrying Current

(Amp.)

Voltamperes

Make Break

Make Break

AC15/ B300

120

30

3

5

3600

360

AC15/ B300

240

15

1.5

5

3600

360

Maximum AC Contact Rating Per Pole (50/60 hz) Same Polarity

DC13/ Q300

240

0.27

0.27

2.5

69

69

Operating Characteristics

Actuation Speed, Max.

250 mm/s

Actuation Speed, Min.

100 mm/min

Actuation Frequency, Max.

6000 ops/hr

Mechanical Life

1 x 10

7

operations at room temperature

Environmental

Enclosure Type Rating

NEMA 1, IP66/IP67/IP69K

Operating Temperature [C (F)] 2…70 ° (35.6…158 °)
Pollution Degree

3

Physical Characteristics

Housing Material

Die cast alloy

Actuator Material

Various polymers and metals

Mounting

2 x M4, any position

Vibration

IEC 68-2-6 (10…55 Hz, 0.35 mm
amplitude)

Shock

IEC 68-2-7 (30 Gn 3 pulses per axis)

Connection

2 m (6.5 ft) cable

Enclosure Color

Red body/black head