Rockwell Automation 800Z Touch Button and Guard Installation User Manual

Touch button and guard installation, Bulletin 800z), Operation

Advertising
background image

BROWN

(+) L1

BROWN (+) L1

BLUE (–) L2

BLACK (N.O.)

WHITE (N.C.)

Electrical Connections: 10-40V DC & 20-30V AC,

100-240V AC

Specifications (relay output)

Touch Button and Guard Installation

(Bulletin 800Z)

1

2

5

4

2

3

1

4

Mini QD (30.5mm)
#889N-F5AE-6F
#889N-F5AE-12F
#889N-F5AE-20F
#889N-R5AE-6F
#889N-R5AE-12F
#889N-R5AE-20F

Micro QD (22.5mm)
#889D-F5AC-2
#889D-F5AC-5
#889D-F5AC-10

WHITE

(1 N.C.)

BLUE
(–) L2

BLACK

(1 N.O.)

BLACK

(1 N.O.)

BROWN

(+) L1

BLUE
(–) L2

WHITE

(1 N.C.)

Cable Option Quick Disconnect (QD) Option

Input Voltage: 10-40V DC, 20-30V AC (800Z-GL...)

Protection: Type 4/4X/13, IP66,1200 psi Washdown

Output Rating:

Min. Load: 6mA, 12V

Operation

1. When the power LED is green, the Touch Button is ready for operation.

2. To enable an output, simply place palm or fingers onto ergonomically contoured surface (see Fig. 1).

3. Touch Button output stays activated as long as the sensor surface remains touched.

4. When the output LED is red, the output is de-energized. When the output LED is green,

the output is energized.

Diagnostics

Code 1: The Power/Fault LED (see Figure 2) will turn red for 1 second during power-up. After the unit

self-diagnostics have passed, the Power/Fault LED will turn green and the Output LED will turn red. If

a fault occurs, the Power/Fault LED will remain red.

Code 2: If the device is touched during power-up, the Power/Fault LED will flash red indicating the

device has been disabled. It will continue to flash until power is cycled to the unit.
Code 3: If the unit detects an unacceptable level of noise, it will become disabled and the

red Power/Fault LED will flash until the noise subsides.
Code 4: If conductive films deposit on the sensor surface over time or if a person attempts to defeat

the sensors with foreign objects, the red Power/Fault LED will flash. The fault will disable the unit and

it will remain disabled until the fault is cleared. (fast flash)

Note: In most applications, the grounded neutral line and/or parasitic capacitance between the input

power leads and earth provide(s) sufficient impedance for the device to function properly. If the unit

powers up normally without diagnostic fault codes but does not activate, the power source could be

ungrounded. For additional information, please contact Rockwell Automation Technical Support by

email at [email protected] or by phone at 440-646-5800.

Figure 1

Figure 2

Sensor Surface

Output LED

Power/Fault LED

CODE TYPE

CODE 2

POWER-UP SAFETY
NOISE DETECTION

CODE 3

DESCRIPTION

FAULT LED FLASH

SEQUENCE

MARGIN DETECTION

CODE 4

• • • • • •

• • • • • • • • •

• • • • • • • • • • • •

WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Protect cables

from mechanical damage during installation and use.


ATTENTION:

The 800Z touch button is designed to be an ergonomic replacement for a palm button. It is not a safety

device by itself. This product may cause personal injury or property damage if not installed and used in accordance with

the manufacturer's instructions provided as well as applicable standards and regulations. The user has responsibility to

ensure that all local, state, as well as, national laws, codes and regulations relating to the use and installation of this

device are satisfied. Furthermore, safety relays should be used in all two-hand control applications. Some U.S. standards

applicable to two-hand control systems include: ANSI B11, NFPA 79, and ANSI/RIA R15.06. Some European standards

applicable to two-hand control systems include: EN 574, EN 999, EN 60204-1, EN 292-1 and EN 292-2.
ATTENTION:

This product has undergone a series change from series B to C. Series C product is RoHS compliant.

Agency Certification:

UL, cUL, and CE compliant for all applicable directives.

CE directives include EN 61000-6-2, EN 50081–2,

and EN 60947–5–1. This product is intended for use in an

industrial environment.

Response Time: Off Time Delay: 60 ms (max.)
On Time Delay: 76 ms (max.), 60 ms (avg.)

800Z-GF3

POWER/FAULT

OUTPUT

Cat

C

Ser

5-Pin Molded Cordsets

Mini QD (30.5mm) Micro QD (22.5mm)

GRAY (COMMON)

3

GRAY

(COMMON)

5

GRAY

(COMMON)

100-240V AC (800Z-GF...)

Inductive: C300, AC-15, I

th

=2.5A

R300, DC-13, I

th

=1.0A

Resistive (connector option): 4A, 250V AC
4A, 24V DC

Resistive (cable option): 3A, 250V AC

3A, 24V DC

Overcurrent protection shall be provided: 3A, 250V

129.3mm

(5.09")

111.9mm

(4.40")

69.8mm

(2.75")

42.3mm

(1.67")

81.6kg (180 lbs) MAX

Maintenance

Unit has no customer serviceable parts.

1 SIDE PRINTED,
BODY STOCK WHITE,
BODY INK BLACK

8-1/2" x 11"

4-1/4 x 2-3/4"

PN-54018

FLAT

FOLDED

SIZE

MATERIAL

SUPR.

MAT.

NO.

Cable should be protected

Remove Ring For
30mm Mounting

Not Used
on 22mm Mounting

1 - 4mm (0.04"- 0.16") With Guard
1 - 9.5mm (0.04"- 0.37") Without Guard

Installation

Guard 800Z-G3AG_

22.3mm (0.878") 800Z-G_2_ _
30.5mm (1.200") 800Z-G_3_ _

2.8 Nm (25 LB-IN) 800Z-G_2_ _
3.9 Nm (35 LB-IN) 800Z-G_3_ _

800Z-G3ALC1

----

MIN. CYCLE TIME

CYCLE POWER REQ.

10 SEC.
1.5 SEC.

BUL. 800Z TOUCH BUTTON AND GUARD INSTALLATION
GP RELAY VERSION INSTRUCTION SHEET
(ENGLISH)

10000071388

01

M. GUELMI

03-17-10

1

1

B

DIR 10000071388 (Version 01)

Printed in U.S.A

PN-54018