Communication Module MSR240

6


Via RS485 following protocol is transmitted:

1. Start byte: 02
2. Address:

Address (0..31 dec)

3. Device Status:

bit0: 1: device ready for start / 0: not ready for start (or already busy)

bit1: 1: Stop signal, 0: all Inputs OK

bit2: 1: Cross fault, 0: No cross fault

bit3: 1: auto start, 0: monitored Start

bit4: 1:

relay energised /

0:

de-energised

bit5: 1: EDM dynamic / 0: Feedback loop static

bit6: 1: Feedback loop open if unit is ready

bit7: 1


4. Input Status of Modules 1-3:

bit0: Stop signal Base Module Input 1

bit1: Stop signal Base Module Input 2

bit2:

Stop

signal

EW1

Input1

bit3:

Stop

signal

EW1

Input2

bit4:

Stop

signal

EW2

Input1

bit5:

Stop

signal

EW2

Input2

bit6: Crossfault on input signal lines

bit7: 1

5. Input Status of Modules 4-6:

bit0: Stop signal EW3 Input1

bit1:

Stop

signal

EW3

Input2

bit2:

Stop

signal

EW4

Input1

bit3:

Stop

signal

EW4

Input2

bit4:

Stop

signal

EW5

Input1

bit5:

Stop

signal

EW5

Input2

bit6:

internal

failure

bit7: 1

6. Input Status of Modules 7-9:

bit0: Stop signal EW6 Input1

bit1:

Stop

signal

EW6

Input2

bit2:

Stop

signal

EW7

Input1

bit3:

Stop

signal

EW7

Input2

bit4:

Stop

signal

EW8

Input1

bit5:

Stop

signal

EW8

Input2

bit6:

unused

bit7: 1

7. Input Status of Modules 10-11:

bit0: Stop signal EW9 Input1

bit1:

Stop

signal

EW9

Input2

bit2:

Stop

signal

EW10

Input1

bit3:

Stop

signal

EW10

Input2

bit4:

unused

bit5:

unused

bit6:

unused

bit7: 1

8. XOR-Check:

XOR-connection of Bytes 2 - 7 (optional)

9. (8.) End byte:

03