845py — fw — 2 — c, Ab c a b

Advertising
background image

Installation Instructions

Size 20 Digital Tachometer, Bulletin 845PY

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Specifications

Electrical

Code Format Incremental, 2 channels

Quadrature 90° ±22°

Channel A leads B CCW

Symmetry 50% ±10%

Power

Requirements

Determined by catalog number:

5V DC ±5% @ 150mA maximum

11-20V DC @ 150mA maximum

24V DC @ 150mA maximum

Frequency

Response

210kHz

Operating Speed (100kHz x 60)/pulses per revolution = RPM or

15,000 RPM, whichever is lower

Resolution Up to 3000 PPR on code disk

Output Drive

Capability

Differential line driver = ±20mA

Mechanical

Starting Torque 2.5 Ncm typical (3.5inĆoz)

Running Torque 2.5 Ncm typical (3.5inĆoz)

Slew Speed 15,000 RPM

Shaft Loading Axial:359N (80lbs)

Radial:222N (50lbs)

Shaft Size 7.94mm (5/16in) diameter

Environmental

Housing NEMA Type 4, IP66 (IEC 529)

Temperature 0°C to +60°C (+32°F to +140°F) Ċ operating

-25°C to +90°C (-13°F to +194°F) Ċ storage

Humidity 98%, noncondensing

Shock 50g (11ms duration)

Vibration 20g (5 to 2000Hz)

Approximate

Shipping Weight

0.56kg (20oz)

Accessories

Description

Part Number

PreĆWired Cables

845-CA-PY-*

Mating Connectors

845-10P, 845-10P-RT

Differential Encoder Buffer Board

845-BB

Selection

845PY —

FW

2

C

a

b

c

a

b

Resolution

Power Supply Optiontor

Code

Description

Code

Description

AM

5

1

5V DC ±5%

BG

10

2

11-20V DC

CA

50

3

24V DC ±10%

CB

60

CE

64

c

CF

80

Mating Connector

CG

100

Code

Description

DB

120

Blank

Without Mating Connector

DF

150

C

With Mating Connector

EB

180

CH

200

CJ

250

CC

254

CW

256

EG

300

CK

360

CL

400

CM

500

DW

512

EH

600

DG

720

DL

800

LG

900

CN

1000

FW

1024

EL

1200

CD

1250

RF

1280

CU

1472

EM

1500

FL

1600

CP

1800

DN

2000

CS

2048

HL

2400

CR

2500

CY

2540

LJ

2750

EN

3000

Advertising