Rockwell Automation 25B PowerFlex 520-Series EMC Plate User Manual
Powerflex 520-series emc plate installation, Installation instructions
 
Publication 520-IN007B-EN-P - September 2013
Installation Instructions
PowerFlex 520-Series EMC Plate Installation
Catalog Numbers: 25-EMC1-FA, 25-EMC1-7FB, 25-EMC1-FC, 25-EMC1-FD, 25-EMC1-FE
Frame A – 25-EMC1-FA
Frame D – 25-EMC1-FD
Frame B – 25-EMC1-FB
Frame C – 25-EMC1-FC
Frame E – 25-EMC1-FE
L1
L2
L3
O
I
1
DC+ DC–
0V
0V
2
Wait three minutes 
after shutdown for 
capacitors to discharge 
to safe voltage levels.
Wire retaining clips included in each kit
IMPORTANT
Grounding and Wiring configuration must be appropriate for EMC applications. Refer to the Wiring and Grounding Guide, (PWM) 
AC Drives manual (publica
or detailed information.
2 x M3
0.39...0.588 Nm
(3.47...5.21 lb-in)
M3
3
4 x M4
0.588...0.785 Nm
(5.21...6.94 lb-in)
M4
2 x M4
0.588...0.785 Nm
(5.21...6.94 lb-in)
M4
4
Note: All required screws are supplied.
Install the EMC Plate
For Frame A...C
Install Wire Retaining Clips and Grounding Screws
For Frame A...C