5technical data – Rockwell Automation 840E Solid-State Level Sensors User Manual

Page 17

Advertising
background image

Technical Data

15

5

Technical Data

5. 1

Power Supply

DC-PNP with M12 connector

10...35 V DC

Supply voltage

< 825 mW

Power consumption

< 15 mA

Current consumption

AC with NPT 1/2 valve connector

19...253 V AC

Supply voltage

< 810 mW

Power consumption

< 3.8 mA

Current consumption

5. 2

Performance characteristics

Switching delay

0.5 s when covering
1.0 s when free

Resolution

< 0.5 mm (0.02 in.)

Maximum error

13.0 +/- 1 mm (0.51 in. +/- 0.04 in.)

Repeatability

+/- 0.5 mm (+/- 0.02 in.)

Hysteresis

3.0 +/- 0.5 mm (0.12 in. +/- 0.02 in.)

Settling time

< 2 s

Reference operating conditions

Ambient temperature: 23 °C (73 °F)
Process pressure:

14.5 psi

Medium:

Water

Medium density:

1

Medium temperature:

23 °C (73 °F)

Installation from above
Density setting:

> 0.7 SGU

Advertising