Rockwell Automation 440P WM3A Wide Roller with Short Lever User Manual

Rockwell Automation Equipment

Advertising
background image

Installation and Operating Instructions

Bulletin 440P-WM3A Wide Roller with Short Lever

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

This publication does not include all specifications, dimensions, or any special installa-

tion considerations. Refer to the product catalog pages for additional information.

General Data

• Designed for 440P-M short lever limit switches
• Wide roller
• Roller diameter 13.5 mm (0.53 in.) x width 25.4 mm (1 in.)
• Lever radius 35 mm (1.5 in.)
• Lever length 55 mm (1.77 in.)
• Includes Allen head screw

Principles, Standards, and Implementation

Operating specifications must be followed. Actuators should
be displaced beyond the point where direct opening action
occurs. If adjustable actuators become loose they may defeat
the direct opening action feature of the limit switch. These
devices are not to be used to directly control a motor.

ATTENTION

To avoid electrical shock and unintended operation of
equipment, disconnect all power to the limit switch and
the controlled equipment before proceeding with any
repair or adjustment of the limit switch.

ATTENTION

Installation of Allen-Bradley limit switches should be in

accordance with local and/or national codes. Servicing

energized industrial control equipment can be

hazardous if not in accordance with recommended

safety procedures.

For safety applications, Rockwell Automation

recommends replacing the complete limit switch.

Approximate Dimensions [mm (in.)]

Instructions

1. Mount lever on shaft in desired position.

2. Torque Allen head screw to 1.5…2.1 N•m

(13.28…18.59 lb•in).

Torque Specifications

Location

Torque

4 mm Allen head screw 1.5…2.1 N•m (13.28…18.59 lb•in)

M4 Screw

35.4

(1.394)

11.5

(0.453)

13.5 dia

(0.532 dia)

7.2 dia

(0.284 dia)

16.0

(0.630)

Advertising