Load Current
AC: 4 to 25mA
. . . . . . . . . . . .
DC: 2 to 25mA
Leakage Current
≤1.7mA at 120V
. . . . . . . . .
Operating Voltage
20--132V AC/DC
. . . . . . . .
Voltage Drop
≤10V
. . . . . . . . . . . .
Repeatability
10% typical
. . . . . . . . . . . .
Hysteresis
10% typical
. . . . . . . . . . . . . . .
Transient Noise Protection
Incorporated
Short Circuit Protection
Incorporated
. . .
False Pulse Protection
Incorporated
. . . .
Overload Protection
Incorporated
. . . . . .
Radio Frequency Protection Min. 10V per Meter,
Frequency range 20--1000 MHz
Shock and Vibration
5G, 30--120 Hz
. . . . . .
UL Approved
Listed
. . . . . . . . . . . .
CSA Approved
Certified
. . . . . . . . . . .
Enclosure
NEMA 1, 2, 3, 4, 12, 13
. . . . . . . . . . . . . . .
IP65 (IEC529)
Self extinguishing glass reinforced
polyester body
Hazardous Location
Division 2, Class I Groups A, B, C & D;
. . . . . .
Class II Groups F & G; Class III
LED
RED: Power; RED: Output
. . . . . . . . . . . . . . . . . . . .
Operating Temperature:
--25
o
C to + 75
o
C
. . .
(--13
o
F to 167
o
F)