871P VersaCubet Proximity Sensor

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

This publication does not include specifications, dimensions, and other installation considerations.

Refer to the product catalog pages for additional information.

!

ATTENTION: Solid-state devices can be susceptible to radio frequency interference (RFI) depending on the power

and the frequency of the transmitting source. If RF transmitting equipment is to be used in the vicinity
of the solid state devices, thorough testing should be performed to assure that transmitter operation is
restricted to a safe operating distance from the control equipment and its wiring.

If a hazardous condition can result from unintended operation of this device, access to the hazardous
area should be guarded.

Wiring

All external wiring should conform to the National Electric
Code and applicable local codes. Connect the proximity
switch to the power supply and load as shown in the wiring
diagrams below. If the positive (+) and negative (–) wires on
DC switches are reversed, the switch will not operate properly.

Wiring Diagrams for AC/DC Switches

Cable

Note 1: Attach housing to ground.

Load

Brown

Blue

20–250V AC/DC

Normally Open or Normally Closed

Mini-Connector

Normally Open or Normally Closed

Note 1: Attach housing to ground.

Load

1

3

2

20–250V AC/DC

Micro-Connector

Normally Open or Normally Closed

Note 1: Attach housing to ground.

Load

1

2

3

20–250V AC/DC

Wiring Diagrams for DC Switches

Cable

Normally Open or Normally Closed

NPN (Sinking)

PNP (Sourcing)

+

10–60V DC

Load

Blue

+

Black

+

Load

Brown

+

Black

Blue

10–60V DC

Brown

Mini-Connector

Normally Open or Normally Closed

PNP (Sourcing)

NPN (Sinking)

1 4
2 3

-

Load

+

10–60V DC

+

-

+

Load

-

-

+

4

1

3

2

10–60V DC

Micro-Connector

Normally Open or Normally Closed

PNP (Sourcing)

NPN (Sinking)

Load

10–60V DC

+

-

-

+

10–60V DC

4

1

2

3

4

1

2

3

Load

-

+

-

+

Note:

Unit must be mounted to a grounded metal frame or grounded via a field wiring lug per NEC requirements.
Recommended grounding lug is available in Allen-Bradley mounting kit 871A–PKIT.