2

Contact Opening Characteristics

Wiring Diagram

Maintenance

These devices require little maintenance, but routine visual
inspection is recommended to keep foreign debris from
collecting on the exterior actuators and rollers. Removing the
operator head is not recommended as loose internal
components may be lost or improperly re-installed.

Actuation Guidelines

The method of actuation and over travel has significant
influence on the service life of the limit switch. To maximize
the service life, it is recommended to provide an actuator with
a 30° pressure angle and a surface hardness of Rc-45 max.

Under no circumstances must the switch be
actuated beyond the mechanical travel specified.
Serious damage to the device and property could
result.

Open

Closed

Positive Opening Point

Plunger Type

0 mm 1.4 mm 2.6 mm 5.5 mm

11-12
21-22

11-12
21-22

85° 41° 26° 0° 26° 41° 85°

Lever Type

Safety Input 1

Safety Input 2

Zb

Safety Output 1

Safety Output 2

Ground

60°

60°

30°

30°

ATTENTION

Lever Positioning

Some rotary switches are supplied with levers that are
mechanically coupled to the actuating shaft. The lever may be
removed and re-installed for cam tracking adjustment. See
table below for torque recommendations.

Torque Specifications

Location

Torque

3.5 mm Operator Head Phillips Screws

0.8 N•m (7.1 lb•in)

Short and Wide Roller Lever Arm
8 mm Hex Nut

1.0 N•m (8.85 lb•in)

Adjustable Lever Arm
4 mm Allen Head Screw

1.8…2.8 N•m
(15.93…24.78 lb•in)

Adjustable Lever Arm Collar
3 mm Allen Head Screw

3.2 N•m (28.32 lb•in)

12 mm Panel Mount Nut

1.5 N•m (13.28 lb•in)