Rockwell Automation 440P-WA1B Lever with Wide Roller User Manual

Rockwell Automation Equipment

Advertising
background image

Installation and Operating Instructions

Bulletin 440P-WA1B Lever with Wide Roller

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

This publication does not include all specifications, dimensions, or any special installation considerations.

Refer to the product catalog pages for additional information.

General Data

• Designed for 440P-A short lever with wide roller limit

switches

• Nylon roller
• Roller diameter 13.5 mm (0.53 in.) x width 25.4 mm (1 in.)
• Lever radius 25 mm (0.98 in.)
• Lever length 40 mm (1.57 in.)
• Includes lock nut and washer

Principles, Standards, and Implementation

Operating specifications must be followed. Actuators should
be displaced beyond the point where direct opening action
occurs. If adjustable actuators become loose they may defeat
the direct opening action feature of the limit switch. These
devices are not to be used to directly control a motor.

ATTENTION: To avoid electrical shock and unintended

operation of equipment, disconnect all
power to the limit switch and the controlled
equipment before proceeding with any
repair or adjustment of the limit switch.

IMPORTANT: Installation of Allen-Bradley limit switches should be in

accordance with local and/or national codes. Servicing
energized industrial control equipment can be hazarous if
not in accordance to recommended safety procedures.

Lever with wide roller

shown installed.

Dimensions [mm (in.)]

Instructions

1. Mount lever arm on keyed shaft in desired position.

2. Install washer.

3. Install Hex lock nut.

4. Torque Hex lock nut to 1…1.4 N•m (8.85…12.39 lb•in).

ATTENTION: For safety applications

Rockwell Automation recommends
replacing the complete limit switch.

Advertising