Analog Sensor Instructions:
Teaching Set Point Limits

• The analog output mode returns a 4…20 mA or 0…10V DC

signal proportional to the measured value.

• The upper and lower adjustment range can be scaled to

distance-fixed window.

• The sensor is taught using an easy four-step remote teach

process or an optional programming cable.

• Two output functions: rising and falling ramp.

Rising Ramp: current or voltage values rise as the distance
increases between the target and the sensor.

Follow the steps below in the order they appear.

1. Place the target at the lower (near) set point limit.

2. Connect to 0V DC [–] using the white wire, or press A1 on the

optional programming cable.

3. Place the target at the upper (far) set point limit.

4. Connect to 10…30V DC [+] using the white wire, or press A2 on

the optional programming cable.

Falling Ramp: current or voltage values fall as the distance
increases between the target and the sensor.

Follow the steps below in the order they appear.

1. Place the target at the lower (far) set point limit.

2. Connect to 10…30V DC [+] using the white wire, or press A2 on

the optional programming cable.

3. Place the target at the upper (near) set point limit.

4. Connect to 0V DC [–] using the white wire, or press A1 on the

optional programming cable.

Analog Sensor LED Indicators

Operating Mode

Red LED

Yellow LED

Green LED

Teach Mode

Target Detected

One flash

Continuous flash

Off

No Target Detected

Flashes

Off

Target Marginal (invalid teach)

Standard Mode

Target present

Off

On

On

Target not present

Off