5–41

Programming

This group of parameters contains the parameters needed for an optional communications
adapter to communicate with the drive.

Adapter I/O

These parameters determine the parameter number
to which PLC output data table or SCANport device
image information will be written. Refer to the A-B
Single Point Remote I/O Adapter manuals or other
SCANport device manual for data link information.

[Data In A1]

[Data In A2]

[Data In B1]

[Data In B2]

[Data In C1]

[Data In C2]

[Data In D1]

[Data In D2]

Parameter Number

111-118

Parameter Type

Read and Write

Display Units / Drive Units

Parameter # / Parameter #

1336 PLUS

SCANport Device

These parameters determine the parameter number
whose value will be read into the PLC input data
table or SCANport device image. Refer to the A-B
Single Point Remote I/O Adapter manuals or other
SCANport device manual for data link information.

[Data Out A1]

[Data Out A2]

[Data Out B1]

[Data Out B2]

[Data Out C1]

[Data Out C2]

[Data Out D1]

[Data Out D2]

Parameter Number

119-126

Parameter Type

Read and Write

Display Units / Drive Units

Parameter # / Parameter #

1336 PLUS

SCANport Device