Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual
Page 103

5–25
Programming
[Traverse Period]
This value sets the time to complete one cycle of
speed modulation.
Parameter Number
78
Parameter Type
Read and Write
Display Units / Drive Units
0.01 Second / Seconds x 100
Factory Default
0.00 Sec
Minimum Value
0.00 Sec
Maximum Value
30.00 Sec
[Max Traverse]
This value sets the peak amplitude of speed
modulation.
Parameter Number
79
Parameter Type
Read and Write
Display Units / Drive Units
0.01 Hertz / 32767 = [Maximum Freq]
Factory Default
0.00 Hz
Minimum Value
0.00 Hz
Maximum Value
50% of [Maximum Freq]
Seconds
Hertz
Maximum Traverse (–)
Traverse
P-Jump
P-Jump (+)
P-Jump (–)
Output
Reference
Traverse Period
–20
0
10
20
30
40
50
60
20
40
Maximum Traverse (+)
Traverse Function
[P Jump]
This value sets the slip or inertia compensation
amplitude of speed modulation.
Parameter Number
80
Parameter Type
Read and Write
Display Units / Drive Units
0.01 Hertz / 32767 = [Maximum Freq]
Factory Default
0.00 Hz
Minimum Value
0.00 Hz
Maximum Value
25% of [Maximum Freq]
Feature Select