Rockwell Automation 1394 Shunt Modules Fuse Replacement Kit User Manual
1394 shunt modules fuse replacement kit, Installation instructions
 
Publication 1394-6.6  March 1999
Installation Instructions
1394 Shunt Modules Fuse Replacement Kit
(Catalog Numbers 1394-SR10, -SR9A, -SR9AF, -SR36A, 
and -SR36AF)
This document illustrates replacing the fuse in the 1394 shunt modules 
(Catalog Numbers 1394-SR10, -SR9A, -SR9AF, -SR36A, and -SR36AF).
Replacing the 1394-SR10
Fuse
To replace the 1394-SR10 shunt module fuse:
1.
Remove power from your system including power to the shunt module.
2.
Locate the fuse holder.
Figure 1
Fuse Holder Location
!
ATTENTION: This system may have multiple 
sources of power. More than one disconnect switch 
may be required to de-energize the system. To avoid 
shock hazard or personal injury, verify that all power 
has been removed before proceeding.
!
ATTENTION: This product contains stored energy 
devices. To avoid hazard of electrical shock, verify that 
all voltage on the capacitors has been discharged before 
attempting to service, repair, or remove this unit. You 
should only attempt the procedures in this document if 
you are qualified to do so and familiar with solid-state 
control equipment and the safety procedures in 
publication NFPA 70E.
To COL
To DC+
Fuse Holder